Are you looking for:

Robinair 34288NI Economy R-134A Recover, Recycle, Recharge Machine

The 34288NI combines simple operation with superior accuracy. It recovers, recycles, evacuates and recharges R-134A mobile A/C systems quickly and accurately. The product outperforms the most current SAE J-2788 standards for accuracy and efficiency, recovering more than 95% of the refrigerant in a vehicle's A/C system and charging to better than +/- 1/2 oz of the programmed charge amount.

Product Specs:

  • Dimension | 107 cm x 61 cm x 76 cm
  • Display | 5 × 9 cm (4.3-in. diag) graphical LCD
  • Filter Capacity | 68 kg (150 lb)
  • Humidity | 32.2°C (90°F), 80% RH non-condensing
  • Gauges | Ø 80 mm (3.15 in.)
  • Max Pressure | Maximum Pressure
  • Noise | <70 dB(A)
  • Operating Voltage | 115V, 60 Hz
  • Oil Drain Bottle Capacity | 355 ml (12 oz)
  • Operating Temperature | 10°C to 50°C (50°F to 122°F)
  • Vacuum Pump | 1.5 CFM (42 L/m) @ 60 Hz
  • Service Hoses | 2.75 m (9 ft) / SAE J2196
  • Internal Tank Capacity | 10 kg (22 lb)

Includes:

  • 34288NI ACS machine
  • Operating Instructions
  • Scale calibration check weight
  • Service Center listing sheet
  • Vacuum pump oil wtih global complaint SDS sheet
  • Compressor oil with global compliant SDS sheet
  • EPA registration sheet/envelope
  • MACS 609 certification info sheet
  • Mobile Vehicle A/C equipment certification form

Features:

  • Automatic Oil Drain: Automatically drains oil recovered during the recovery operation and puts the oil in a graduated container showing the user how much needs to be injected back into the system.
  • Automatic Air Purge: Eliminates damaging air without monitoring gauges or opening valves.
  • 4.3 in full color graphics display
  • Programmable Vacuum Function: Defaults to 15 mins, programmable up to 99 mins. “Remaining time” is displayed.
  • Optional Refrigerant & Oil Database: A/C system capacities for North American market vehicles (Not included with the machine)
  • Refrigerant Management System: Displays refrigerant use and monitors remaining filter life. Prompts appear when 1/3 of filter life remains
  • Optional Printer: Add the ability to print service summaries from the machine (Not included with the machine)
Kiene: Spring Brake 3rd Hand Tool

Replacing a spring brake emergency section and diaphragm requires: juggling the section with one hand, lining up the diaphragm with the other hand and with your third hand, turn a ratchet to tighten the clamping bolts.  This requires dexterity not commonly found. 

Why the Spring Brake 3rd Hand?

  • Replacing the complete spring brake is time consuming, frustrating and often not needed.  By replacing only the emergency section and diaphragm, the job can be done in a few minutes, without removing the service section and without the hassle of measuring and cutting the service section push rod. (A job in itself!)
  • The Spring Brake 3rd Hand holds the emergency section in place leaving both hands free to align the diaphragm and tighten the clamping bolts.  This helps ensure proper diaphragm placement, which results in less service side leaks and costly "come back" jobs.
  • The Spring Brake 3rd Hand makes replacing an emergency section and diaphragm simpler-easier and saves money by minimizing repair time and quickly gets the vehicle back into service.

 

Quick Changer Oil Drain Plug - 1 1/2 in - 12 UNF

Changing your oil can be a messy, time-consuming task. Waiting for the engine to cool wastes valuable shop time. Spilled hot oil makes a mess and, it can burn!

Now convert every vehicle into a Quick-Changer vehicle.

Now you can eliminate these hassles by replacing your standard oil drain plugs with the innovative Quick Changer oil-drain system. It takes only a few minutes, with no special tools required.

Once you've installed the Quick Changer oil drain valve, you can quickly and easily drain the oil at any time, even when the engine is hot. Actually, draining the oil at high temperatures results in a cleaner flush, since the larger dirt particles drain out with the oil.

No more stripped-out oil pans.

Just connect the drain hose to the Quick-Changer valve, which opens automatically. When finished, disconnect the hose. The valve shuts automatically and cleanly. No more mess. No more spilled oil.

Best of all, by eliminating conventional drain plugs, the Quick Changer system prevents oil-pan threads from being stripped. Your oil pans last longer, saving you money. The valve doesn't extend beyond the threaded portion of the drain.

Just look at these Quick-Changer advantages:

  • Eliminates stripped threads and frozen drain plugs
  • Is fully leak-proof unique design prevents accidental valve openings
  • Draws oil samples quickly and easily, with full control over oil flow
  • Valve and drain assembly fabricated in corrosion-resistant brass
  • Available in metric and U.S. sizes to fit all engines
  • Safe, clean, environmentally friendly operation
  • Meets rigorous independent test lab standards
  • Drains oil faster than conventional drain plugs
Navistar Diamond Logic Builder OEM Software

NAVISTAR® DLB FLEET

Diagnostic Software

International® Diamond Logic® Builder Fleet

Basic Functions

  • Read Fault and clear diagnostic fault codes
  • View vehicle parameters and features

Advanced Features

  • Bi-directional control of electrical components
  • View switch location and cluster configuration
  • View wiring diagrams
  • Automatic module detection<
  • Graph parameters<
  • Record snapshots

Compatible Vehicles

  • International® 4200/4300/4400 Series
  • International® 7000 Series
  • International® 8000 Series
  • International® CF Series (Cluster faults, Test all gauges except fuel, Odometer reset)

Diamond Logic Builder™ (DLB) provides high performance diagnostics for the electrical systems on high performance International trucks and IC Buses. DLB Fleet displays vehicle signals in graphical and text format. This software also reads and displays vehicle diagnostic trouble codes as well as vehicle features and parameters.

Minimum Requirements:

  • 150MB of free hard disk space
  • An Internet connection

Recommended Requirements:

  • Pentium 4 class process with a minimum 1 GHz of speed
  • 512 MB of RAM
  • 150MB of free hard disk space
  • Operating System of Windows 7, XP, 2000 or Vista
  • One or more RP1210A compatible communication devices
  • Any type of high speed Internet connection

Recommended Adapters:

  • NEXIQ™ Technologies – USB­Link2
  • Dearborn Group Technologies – DPA IV, DPA IV+
  • Noregon® Systems, Inc. – DLA+, DLA+ Wireless

Communication Link Drivers:

  • DLB uses standard RP1210A drivers for communication. The drivers are specific to the communications device and are not installed with DLB.

User Permissions:

Diamond Logic Builder has different tiered permission levels allowing for more advanced use of the software.

  • Level 1 (Diagnostics) – L1 is included with active product key.
  • Level 2 (Diagnostics and Parameter Programming) – L2 access requires completion of web based training for each user.
  • Level 3 (Diagnostics, Parameter Programming and Advanced Logic) – L3 access requires completion of Instructor Led training for each user.